================================================================================ Intel(R) Xeon(R) Processor-Based Server BIOS Development ================================================================================ INTEL Enterprise Products and Services Division Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA ================================================================================ DATE : Mar. 09, 2012 TO : Intel(R) Xeon(R) Processor-Based Server Platform customers SUBJECT : BIOS Release notes for version R0061 ================================================================================ LEGAL INFORMATION ================================================================================ Information in this document is provided in connection with Intel Products and for the purpose of supporting Intel developed server boards and systems. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (C) 2012 Intel Corporation. ================================================================================ ABOUT THIS RELEASE ================================================================================ Build Stamp : S5500.86B.01.00.0061.03092012 1535 Build Date : Mar. 09, 2012 ================================================================================ BIOS COMPONENTS/CONTENTS ================================================================================ Processors supported: Intel(R) Xeon(R) Processor 5500 series and Intel(R) Xeon(R) Processor 5600 series w/ <= 6.40GT/s Max Intel(R) QuickPath Interconnect Speed Microcode update versions: CPUID Version Status 0x106A4 0x00000011 Production (Intel(R) Xeon(R) Processor 5500 series C0/C1) 0x106A5 0x00000016 Production (Intel(R) Xeon(R) Processor 5500 series D0) 0x206C2 0x00000015 Production (Intel(R) Xeon(R) Processor 5600 series B1) On-Board Component Option ROM Versions: IBMC Matrox VGA : VBE BIOS V3.8SM ICH9R/ICH10 AHCI Option ROM : iSrc 1.18_E 05012008 ICH10 SATA SW-RAID Option ROM : vA.10.02251631I 82575EB iSCSI Boot Option ROM : v2.2.96 82567LM, 82571EB, 82574L& 82576 PXE Version : Intel(R) Boot Agent GE v1.3.27 82575EB PXE Version : Intel(R) Boot Agent GE v1.3.71 82599EB PXE Version : Intel(R) Boot Agent XG v2.1.30 Alpha-3 Intel(R) QPI Reference Code Version : 1.85 Memory Reference Code Version : 2.21 Intel(R) Xeon(R) Processor 5600 series BIOS ACM version: 1.3 Intel(R) Xeon(R) Processor 5600 series SINIT ACM version: 1.1 Management Engine Firmware Version : SPS_01.01.02.007.0 Production #3 ================================================================================ SYSTEM FIRMWARE REQUIREMENTS ================================================================================ BIOS Update Utility: UEFI iFlash32 2.6 Build 15 Production boards: Product Fab Version BMC FRUDSR EEPROM HSC S5500BC Fab3, Fab4 00.34 FBC_12 1.1 2.09 S5520HC Fab3, Fab4 00.34 FHC_15 1.3 2.09 S5500HCV Fab3, Fab4 00.34 FHC_15 1.3 2.09 S5520SC Fab2 00.34 FHC_15 1.3 2.09 S5520UR Fab3->Fab6 00.34 FUR_14 1.3 2.09 S5500WB Fab1->Fab3 00.34 FWB_07 1.4 N/A S5500WB12V Fab1->Fab3 00.34 FWB_07 1.4 N/A The following update process must be followed to ensure a trouble free update from the BIOS R0025/R0025.1, BMC00.28 releases. 1. BMC firmware to 00.34 or later 2. BIOS R0033 or later 3. Manageability Engine (ME) firmware 01.10 or later 4. Latest FRU/SDR package specific to the baseboard. ================================================================================ INSTALLATION NOTES ================================================================================ WARNING: It is very important to follow these instructions as they are written. Failure to update using the proper procedure may cause damage to your system. Updating from BIOS revisions R0018 or later: User can update BIOS flash image via either of the following methods... UEFI iFlash32 2.6 Build 10 1. Boot the system to EFI Shell 2. Copy IFlash32.efi and R0061.CAP file to a HD or USB Flash Drive ( Do not use the Rec.CAP file as it will clear NVRAM and should only be used for Recovery - See Recovery Instructions located in the seperate recovery package ) 3. Map the respective storage device in system with the command Shell> map -r 4. Change the Shell to mapped device file system Example: Shell> fs0: (or fs1:) 5. Run the IFlash32 utility on the prompt fs0:\> IFlash32 [File Name] /u /ni 6. Reboot system after the update is completed. ================================================================================ BIOS RECOVERY INSTRUCTIONS ================================================================================ The recovery instructions and recovery files are now located in a separate package available for download. ================================================================================ KNOWN ISSUES/WORKAROUNDS ================================================================================ - The UEFI iFlash32 BIOS Update Utility should only be used after the R0018 or later BIOS version is properly installed on your system. Refer to the section regarding INSTALLATION NOTES above. - If performing BIOS recovery process and the system hangs at POST Code 0x34 before the BIOS POST screen appears, it may a require a warm reset via the front panel or AC power cycle for recovery to properly detect the recovery media and load FVMAIN.FV from the recovery device. - For S5500BC, S5520HC, S5500HCV, S5520SC, S5520UR, S5500WB & S5500WB12V Platforms, please ensure that the BMC FW installed is v0.31 or later before updating to the R0029 or later BIOS release. Using BIOS R0029 with any BMC FW prior to v0.31 could cause the system to automatically shutdown upon A/C power cycles. - BIOS R0037 requires a firm key press during POST to get a key accepted. - BIOS R0048 and later: Intel(R) Xeon(R) Processor 5600 series A0 stepping no longer supported. - BIOS R54 has implemented the Recovery process enhancement solution to fix the recovery dependency of the BIOS variables. When customer enables both recovery Jumper and Clear CMOS jumper, BIOS variables in VPD area will be cleared and CMOS values will be set to default. ================================================================================ R0061 ================================================================================ - Fixed: System Cache Type of L1 cache is incorrect in SMBIOS. - Fixed: Unable to execute Intel(R) utilities when a forced EFI boot is used in Shell script. - Fixed: USB Boot Priority fails after removing disk 0 in some specific configuration. - Fixed: 64bit Memory Mapped I/O is limited to 4GB. - Fixed: Admin and user password should be set to the same in BIOS. - Fixed: System halt in OS MP initiation in reboot cycle test under specific configuration with the Intel(R) Xeon processor X5670. - Fixed: System UUID should not be blank when BMC is set to force update mode. - Fixed: BIOS POST may hang with external USB HDD(4KB sector) connected. - Fixed: System met BSOD when installing Windows* server 2008 R2 with EFI optimized boot enabled. Other: - Added: BIOS Power On password feature. - Added: Implement the SINIT ACM to BIOS image. - Added: Increase the hit rate of pressing the F2 key to enter BIOS setup page when booting up. - Update new microcode for Intel(R) Xeon S5600 series processor. - Update ACM Binary to version 1.3 for Intel(R) Xeon S5600 series processor. ================================================================================ R0060 ================================================================================ - Fixed: Update Intel(R) Xeon(R) Processor 5500 series D0 stepping microcode to 16. - Fixed: Update Intel(R) Xeon(R) Processor 5600 series B1 stepping microcode to 14. - Fixed: BIOS R0057 fails Node Manager Power Capping on Intel(R) Server Board S5500WBR. - Fixed: Add fix to address some PCIE cards cold reset failure. Other: - Added: update ICH10 SATA SW-RAID Option ROM to support 3TB HDD. ================================================================================ R0059 ================================================================================ - Fixed: CPU frequency in BIOS setup is not shown correctly with BIOS58 on some platforms. ================================================================================ R0058 ================================================================================ - Fixed: It takes more than 50s to stay at Windows 2003 R2 SP2 login page on RAID ESRTII with Intel(R) Sever Board S5500BC. - Fixed: L1 Cache Size is not correct in SMBIOS when plug 2 Intel(R) Xeon(R) Processor E5620. - Fixed: [X] USB Stick Hangs POST on Intel(R) Sever Board S5520UR - Fixed: Wrong hard disk capacity reported in BIOS setup and SATA RAID configuration page Other: - Added: RMM3 password via BIOS setup will accept special characters - Added: NSG Passive: Support 2U 4X PCIe Riser on Intel(R) Server Board S5520UR. - Added: Support 2U Butterfly Passive Riser on Intel(R) Server Board S5520UR. - Update: EFI NIC Driver to version 4.5.14 - Update: PXE Boot Agent OPROM to version 1.3.71 - Update: Intel(R) Xeon(R) Processor 5500 series D0 microcode to version 0x15 ================================================================================ R0057 ================================================================================ - Fixed: TPM hardware status can't be changed without the owner's key. - Fixed: Fixed 1-5-4-2 beep after the user changes Virtualization Tech / Hyper Threading setting in BIOS setup. Other: - Added: ACM for Intel(R) Xeon(R) Processor 5600 series update to production V1.2 - Added: Workaround PCI 8400 video card in S5520SC ================================================================================ R0055 ================================================================================ - Fixed: PCIe Capabilities Register "Slot Implemented" bit is not set correctly by BIOS. - Fixed: BIOS refresh rate is extremely slow when the Console Redirection BAUD rate is less than 115.2K. - Fixed: Slow ISCSI boot time to operating system load. - Fixed: Certain graphics cards can't boot with BIOS R0054. - Fixed: PCIe Link speed changes can occur without logging a SEL event. ================================================================================ R0054 ================================================================================ - Fixed: Power button issue on S5500WB Fab 305 with BIOS R0049 and R0050. - Fixed: MRC 2.21 update - Fixed: Enable CRID feature for Intel(R) Xeon(R) processor S5500/S5600 series. - Fixed: CSM update for boot device order issue on S5500BC. - Fixed: update Intel(R) Xeon(R) processor 5600 series Microcode to 0x0F - Fixed: LSI OpRom update to fix HDD offline issue. - Fixed: HSC Revision is incorrect in BIOS setup when HSC is not connected. - Fixed: Microsoft* Windows* 2008 R2 installation failure with Intel(R) 82576/82575 NIC LOM. - Fixed: PCIe Fatal Completion Timeout Error during boot. - Fixed: LAN static IP address will be lost in certain versions of the Microsoft* Windows* operating systems when updating BIOS. Other: - Added: Benchmark Setup Options. - Added: Support for Nvidia 8400 card on S5520SC. - Added: Clear NVRAM area during Recovery Mode. ================================================================================ R0050 ================================================================================ - Fixed: Certain PCI video cards may cause a Fatal Completion Timeout Error during boot. - Fixed: Memory speed is incorrect if memory socket is not populated; - Fixed: AHCI option ROM in setup is still visible when onboard SATA controller is disabled. - Fixed: Display up to 32 characters in the chassis serial number field in BIOS setup. - Fixed: BIOS has video related problems with some 30" monitors in BIOS setup. - Fixed: AES-NI support changed to enabled by default. Other: - Added: LSI SW RAID OPROM rev A.09.04151432I. - Added: Support 6GB SAS module on S5520HC. - Added: SEL event logging if PCIe link speed changes occur. ================================================================================ R0049.1 ================================================================================ - Update Intel(R) Xeon(R) Processor 5600 series B1 Microcode to version 0x0C to products supporting Intel(R) Trusted Execution Technology (Intel(R) TXT). ================================================================================ R0049 ================================================================================ - Fixed: Corrected BIOS string to read Intel(R) Trusted Execution Technology - Added: Authenticated Code Module (ACM) 1.0 ================================================================================ R0048.2 ================================================================================ - Update Intel(R) Xeon(R) Processor 5600 series B1 Microcode to version 0x0C. ================================================================================ R0048 ================================================================================ - Fixed: Console redirection binary update for DC cycle hang issue. - Fixed: Secure Erase procedure causes BIOS hang. - Updated memory reference code to version 2.11. ================================================================================ R0047 ================================================================================ - Fixed: Can not install Microsoft* Windows 2008 with external USB ODD if the internal ODD is removed. - Fixed: Show incorrect information about L3 cache on the Intel(R) Xeon(R) Processor 5600 series B0 12MB processors. - Fixed: BitLocker drive Encryption test fail with Intel(R) Xeon(R) Processor 5600 series. - Fixed: Microsoft* Windows 2000 Adv Server SP4 Intall (Windows fails to Reset). Other: Updated MicroCode to version 0x06/0x05. Enabled Turbo Hysteresis on Intel(R) Xeon(R) Processor 5600 series. ================================================================================ R0046 ================================================================================ - Fixed: Microsoft* Windows* certification test failure. ================================================================================ R0045 ================================================================================ - Fixed: Invalid Date code when using clear CMOS jumper. - Fixed: BIOS Option "Memory Mapped I/O above 4GB" is not functional. - Fixed: BIOS Setup is reporting incorrect version of SDR. - Fixed: CMOS setup options - a disabled serial port can be set as console redirection. - Fixed: Mismatched CPUs Fails to Light Amber LED. - Fixed: System can't enter ERST2 RAID OPROM with the 10G NIC I/O module installed. - Fixed: Pressing to load BIOS defaults will change HyperThreading (HT) from disabled to enabled when processors that don't support HT are installed. - Fixed: Clock Throttling via Linux* SW Control is inoperative. - Fixed: Quantum* DAT72-000* and DLT-V4* were not listed in BIOS setup. Other: Updated MRC to version 1.81. Updated QPIRC to v1.80. Updated SPS 01.01.02.007.0 Production #3 ME FW update. - Added: Support for the Winbond* W25Q64BV* flash device. - Added: Set iBMC mailbox corresponding bits for LVDDR3 DIMMs - Added: Turbo Boost power optimization support. ================================================================================ R0042 ================================================================================ - Fixed: The system may hang after console redirection is enabled in BIOS setup. Other: Intel(R) QPI Reference Code Version update to version 1.75. ================================================================================ R0041 ================================================================================ - Fixed: Incorrect Platform ID for S5500WB S5500WBV. - Fixed: Some Fiber Channel RAID adapters fail in slots 1 & 2 of the 2U PCIe butterfly riser. - Fixed: Prefetchable Memory not being properly allocated to Multiple cards. - Fixed: Processor C3/C6 setting can be changed with user password login. - Fixed: There is an incorrect IO Interrupt Entry in MP Table for onboard LAN. - Fixed: BIOS reverts to OLTT with Temp Sensor enabled UDIMMs. - Fixed: QPI speed mismatch error (0x195) behavior is incorrect. - Fixed: Pressing during POST (network boot) is not protected by the Admin password. - Fixed: The system hangs after pressing "Pause" key. - Fixed: BMC user password setting in BMC Lan configuration only allows 7 of 15 characters. - Fixed: Backplane fault LEDs blinking unreasonably during POST with SWRAID mode enabled. - Fixed: TEAC* DVD-ROM DV-W28S-RZ3 cannot boot under AHCI mode. - Fixed: EFI Shell: 'reconnect -r' locks system after approximately 3 times. - Fixed: FRU Checksum Field is not updated when the serial number is edited in BIOS setup. CCB556: When BMC is in force update mode, the BMC configuration can be edited in BIOS setup. Other: - Added: BMC onboard NIC and RMM3 NIC are configurable via BIOS Setup. - Added: Enchanced manageability (SMBIOS) via OOB. - Added: WorkStation Logo for S5520SC. - Added: LSI Option ROM update A.09.07211059I. - Added: Report POST error code 0x8500 when the system transitions from Mirroring mode to independent mode. - Added: Intel(R) Xeon(R) Processor 5500 series C-0 processor microcode Production patch revision 0x11. ================================================================================ R0038 ================================================================================ - Fixed: No beep code is generated when processor microcode is unavailable for the processor installed. - Fixed: Long delay to enter EFI shell from the BIOS setup menu when AHCI is enabled. - Fixed: Remote system via serial redirection does not show any display prior to entering operating system with Quiet Boot enabled in BIOS setup. - Fixed: With Quiet Boot enabled in BIOS and Console Redirection enabled, the remote system will only display a blank screen after pressing to enter BIOS setup from the remote system. Other: - Updated: help text for C3 and C6 options in BIOS setup. - Updated: help text for Maximize Memory Below 4GB in BIOS setup and further maximized available memory for non-PAE aware operating systems. - Added: Option to change QPI link speed in BIOS Setup. - Updated: BIOS help text for Intel(R) SAS Entry RAID Module ================================================================================ R0037 ================================================================================ - Fixed: When clearing TPM, the status should be "Disables & Deactivated" not "Disabled & Activated". - Fixed: 1064e SAS module ESRTII mode is not compatible with onboard SATA SW RAID. - Fixed: SMBIOS Type 17 Device Set incorrect values. - Fixed: SMBIOS Type 19 Ending Address is incorrect. - Fixed: Removing TPM option from BIOS setup on boards that do not support TPM. - Fixed: PCI-X riser: system hangs with POST code 0xFB when slots 2 and/or 3 are populated. - Fixed: BIOS embedded LAN option ROM is still executed even when the setting is disabled. - Fixed: The first slot of active PCI riser card does not work. - Fixed: Novell* SLES 10* SP1 will not boot with 3 fibre channel adapters installed. - Fixed: Error Manager shows "Passwords cleared by jumper" after a BIOS recovery. - Fixed: HDD LED Activity on backplane is abnormal under RHEL5.3. - Fixed: S5500BC: key response is very slow when Quiet Boot is Enabled - User cannot bypass Splash logo. - Fixed: S5520VI: With BMC-FORCED jumper installed, BIOS disables the SAS controller. - Fixed: BMC fails to connect via RMM3 on IO Mezz. - Fixed: Change data payload size to 256 bytes on S5520UR for certain add-in controllers. - Fixed: If Legacy OS Redirection is Disabled, legacy oprom output is no longer redirected. Other: - Added: C6 and C3 Setup Option in BIOS Setup. - Increased PCIe completion timeout values for Intel NIC devices per Intel recommendation in the following Specifcation Updates: - Intel(R) 82598 10 Gigabit Ethernet Controller Specification Update revision 2.5 - Intel(R) 82575 Gigabit Ethernet Controller Specification Update and Sighting Information version 2.1 - Intel(R) 82576 Gigabit Ethernet Controller Specification Update version 2.2 - Updated SMM memory utilization - Corrected some SMRR bit locks - Add Intel(R) Xeon(R) Processor 5500 series D-0 processor microcode Production Candidate patch revision 0x04 ================================================================================ R0036 ================================================================================ - Fixed: Can't enter the Option-ROM of the SROMBSASMR RAID adapter. - Fixed: SROMBSASMR adapter causes a system lock up and can't enter the OPROM after pressing hot key . - Fixed: Pressing does not show POST screen and fails to enter SATA SW RAID BIOS console when Quiet Boot is enabled. - Fixed: The system will Not override OLTT selection if it can support CLTT. - Fixed: Remote Serial Console is not disconnected when Console Redirection is disabled in BIOS setup. Other: - Corrected: BIOS setup SATA Mode [LEGACY] help Text statement was incorrect. ================================================================================ R0034 ================================================================================ - Fixed: Processor Hyper-Threading setting to disabled will reset to enabled when reentering BIOS setup. - Fixed: OS installation will stop while RAID adapter under RHEL5.3 32bit. - Fixed: OS installation will hang and appear while Loading mptsas driver under RHEL5.3 32bit. - Fixed: Mass Storage Controller Configuration does not display correct information. ================================================================================ R0033 ================================================================================ - Fixed: SW RAID option for ICH10R disappears when AXX4SASMOD is present. - Fixed: Quad port Intel (R) 82576 Gigabit Ethernet Controller Pxe Boot hang booting to RIS server. - Fixed: BIOS Boot order changes with USB device changes. - Fixed: BIOS recovery fails intermittently. - Fixed: DIMM information is incorrect when DIMM population is A1/A2/D2. - Fixed: HDD running in PIO mode and causing poor performance under Microsoft* Windows* 2003. - Fixed: BIOS setup indicates Hyperthreading is enabled for processors without Hyperthreading support. ================================================================================ R0031 ================================================================================ - Fixed: "TPM Administrative Control" Option in Security Menu removed on S5500WB. - Fixed: BIOS Boot Manager Page goes blank on performing load default settings. - Fixed: Platform/Board ID mismatch in BIOS setup. - Fixed: System can't boot to WebBIOS of LSI 1078 midplane with hardware RAID. - Fixed: Cannot go into the LSI RAID BIOS Console when SATA is configured for enhanced or compatibility mode. - Fixed: SAS SW RAID option in BIOS SETUP does not appear when SAS IO module is installed. - Fixed: Qlogic* QLE2464/QLE2564 is not recognized in the 2U PCI riser. - Fixed: Disabling "Intel(R) SAS Entry RAID Module" in bios, removes the entry. ================================================================================ R0030 ================================================================================ - Fixed: ACPI S3 resume hang with Dual-processor and Microsoft* Windows* 2003 32 bit. - Fixed: System will easily hang if greater than 14 USB devices are populated. - Fixed: Intel(R) pro quad port EXPI9404PTL is missing from the Microsoft* Windows* device manager. - Fixed: Unable to install Microsoft* Windows* 2008 x64 UEFI. - Fixed: SuSE* SLES10 reports: Uhhuh. NMI received for unknown reason 20 & 30. - Fixed: System unable to execute BIOS recovery from USB DVD/CD-ROM. - Fixed: Quad NIC IO module boot option disappears when user disables the onboard NIC ROM. - Fixed: Second NIC is missing in BIOS Setup Boot Manager. ================================================================================ R0029 ================================================================================ - Fixed: IOH therm trip doesn't assert an event and shutdown when IOH temperature is increased above the threshold. - Fixed: 1064e based IR card in slot 2 activates incorrect RAID options in BIOS Setup. - Fixed: Intel(R)RAID Controller SRCSATAWB is not getting detected. - Fixed: Intel(R) Integrated RAID Controller SROMBSASMR drives don't appear in Microsoft* Windows* 2008 EMT64. - Fixed: SATA port 4 & 5 device can't be detected in Compatibility & SW RAID mode. - Fixed: After Enabling BIOS Console Redirection, nothing is redirected on the first boot. - Fixed: F2 Setup screen shows Blank under Boot Manager. - Fixed: SUT can not detect device on SATA Port 4/5 in Compatibility Mode under BIOS R0028. ================================================================================ R0028 ================================================================================ - Fixed: Install two config of MBE DIMM mix then system behavior not right. - Fixed: Boot system with iBIST reworked DIMM install don't show expect behavior. - Fixed: Disable SAS RAID function in BIOS menu then Manta Ray cannot be detected. - Fixed: Console Redirection on Serial port A failed. - Fixed: Can't boot to SATA RAID OpROM. - Fixed: S5520SC sometimes boots with 3 beep codes during POST with UDIMM's installed. - Fixed: Microsoft* Vista* 64-Bit installation fails under AHCI mode. ================================================================================ R0026 ================================================================================ - Fixed: TPM driver reports errors during ACPI S3 resume under Microsoft* Vista*. - Fixed: BIOS Setup hangs after "Load Default Values" and "Save Changes". - Fixed: Hotswap USB devices installed while in BIOS setup the system take about 2 minutes to detect the USB device. - Fixed: System can't boot to WebBIOS of add-on storage Card installed on riser. ================================================================================ R0025 ================================================================================ - Fixed: Can't boot to SATA RAID OpROM. - Fixed: No Hard Disk found when selecting SATA Mode as SW RAID. - Fixed: Booting from DVDROM takes approximately 1 minute when in Enhanced Mode. [END OF RELEASE NOTES]