---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 03/02/2005 Version: 7.30.32.0302 ---------------------------------------------------------------------------------------------------------------------------------- Updated Raidmonitor ver.1.26 ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 10/26/2004 Version: 7.30.32.1026 ---------------------------------------------------------------------------------------------------------------------------------- Windows Installer Tracking #: LSID100022492 Customer: None Symptom: Spy.log is marked read-only, cannot write messages to it. Fix: Changed File's attribute. How to validate: Start installation. Check attribute for spy.log. ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 10/13/2004 Version: 7.30.31.1015 ---------------------------------------------------------------------------------------------------------------------------------- Installer was getting Error:1920 ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 10/13/2004 Version: 7.30.31.1013 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser and raidmonitor ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 09/20/2004 Version: 7.30.30.0920 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 09/03/2004 Version: 7.30.29.0903 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser, Monitor Enhancement #1 Windows Installer Tracking #: LSID100016242 Customer: LSI Symptom: Spy version does not change when driver is downgraded. Fix: Created a script that will remove spyser.exe file that driver(or GAM) installation installed from system32 directory during Spy Package installation. How to validate: Make sure you have installed GAM that will register spy from system32 directory. Start Spy installation, this installation will register spy from Programs File folder and remove spyser.exe file from system32 direcotry. ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 08/25/2004 Version: 7.30.28.0825 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 08/23/2004 Version: 7.30.27.0823 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 07/15/2004 Version: 7.30.25.0721 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser Installer Remove driver dependency ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 07/15/2004 Version: 7.30.24.0715 ---------------------------------------------------------------------------------------------------------------------------------- updated spyser and Lsiata.dll ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 06/16/2004 Version: 7.30.22.0616 ---------------------------------------------------------------------------------------------------------------------------------- Updated Raid Monitor ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 05/24/2004 Version: 7.30.22.0524 ---------------------------------------------------------------------------------------------------------------------------------- Windows Installer Tracking #: None Customer: None Symptom: WMI(Windows Management Instrument) was not getting data from spyser during reboot since WMI service was starting before spyser service. Fix: Added spyser dependency under WMI service. How to validate: 1. Install Package. 2. Look under SCM for WMI service. Spyser service have been added as a dependency under WMI service. 3. Remove package, look under SC for WMI service. Spyser service will be removed from WMI service. ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 05/14/2004 Version: 7.30.22.0514 ---------------------------------------------------------------------------------------------------------------------------------- Bug Fix #1 Windows Installer Tracking #: None Customer: None Symptom: 1. Invoke : Setup.exe /s /v"/qn ADDLOCAL=Spyser, Raid_Monitor ", notice that it installs File exist under Program Files\LSI Logic Corp\Spy\... 2. Again invoke install Setup.exe /s /v"/qn ADDLOCAL=Spyser, Raid_Monitor "Notice that files under Program Files\LSI Logic Corp\Spy\... are gone. Fix: Condition was missing for the sequence for silent Install. How to validate: 1. Invoke : Setup.exe /s /v"/qn ADDLOCAL=Spyser, Raid_Monitor ", notice that it installs File exist under Program Files\LSI Logic Corp\Spy\... 2. Again invoke install Setup.exe /s /v"/qn ADDLOCAL=Spyser, Raid_Monitor ". Files under Program Files\LSI Logic Corp\Spy\... should be present. ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 04/29/2004 Version: 7.30.22.0429 ---------------------------------------------------------------------------------------------------------------------------------- Spyser.exe have been updated ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 03/08/2004 Version: 7.30.19.0308 ---------------------------------------------------------------------------------------------------------------------------------- Spyser.exe Tracking #: DFCT 9322 Customer: LSI Symptom: Logical Drive mode for Raid 1 is showing as "1". It should be "Raid 1" Fix: String "1" for Logical Drive mode is changed to "Raid 1" How to validate: Run Test application of Spy and Check for LogicalDrive Mode string . It should be "Raid1" ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 01/23/2003 Version: 7.30.18.0123 ---------------------------------------------------------------------------------------------------------------------------------- Spyser.exe Tracking #: TASK # 7882 Customer: FSC Symptom: For FSC system's Spy is still showing connections as Primary Master, secondary Master etc.. It should be Port # 0, Port # 1.. Fix: Addition of FSC system's Id's in Spy. Spy now distinguishes between PATA and SATA and retruns appropriate strings to client How to validate: Run Spy on FSC system. Remove one drive from RAID1 . Check for messages that appear now. It should be Port # xx Bug Fix #2 Windows Installer Tracking #: LSID100004906 Customer: LSI Symptom: Shows CERC in the Windows registry. Fix: Removed CERC entry from "HKEY_LOCAL_MACHINE\Software\ LSI Logic Corporation" in the registry. How to validate: 1) Install the Package. 2) Go to "HKEY_LOCAL_MACHINE\Software\ LSI Logic Corporation" key in registry. 3) CERC entry should not be present. Enhancements Enhancement #1 Tracking #: TASK # 7881 Customer: LSI Symptom: Adapter Speed need to return as num value Fix: For an adapter, spy now returns Max dapter speed as num How to validate: Run Test application and check for Adapter speed Enhancement #2 Tracking #: TASK # 7881 Customer: LSI Symptom: Adapter Speed is not coming Fix: For an adapter, spy now returns Max dapter speed. How to validate: Run Test application and check for Adapter speed ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 11/25/2003 Version: 7.30.16.1125 ---------------------------------------------------------------------------------------------------------------------------------- Spyser Tracking #: DFCT 6671 Customer: HPQ Symptom: After failing a drive and on rebooting OS, RaidMon icon is not appearing in system tray Fix: Spy project settings for "Project optimization" was wrong. It should be set to "default" instead of "Maximum" How to validate: Run Spy on Japanese OS. Remove 1 drive from RAID1. Shutdown system and insert another drive, configure it as HotSpare and restart the system. Verify that on booting up, RaidMon icon appars in System tray Bug Fix # 2 Spyser Tracking #: DFCT 6695 Customer: HPQ Symptom: After failing a drive when HotSpare kicks in , RaidMon is not popping up messages. These messages appear in Spy.log and in Event Log but RaidMon is not popping up messages. Fix: Spy project settings for "Project optimization" was wrong. It should be set to "default" instead of "Maximum" How to validate: Creat one RAID 1 (PM+SM) . Cretae one HotSpare (PS). Run Spy on Japanese OS, remove 1 drive from RAID1. Check for messges coming from RaidMon Bug Fix # 3 Installer Tracking #: LSID100006793 Customer: HPQ Symptom: Installation fails to upgrade from previos version of Spy. Fix: Changed "Product ID" and Package ID" to uninstall previous version before installing current version. How to validate: Install Spy for MegaIDE package ver. 7.30.15.1114. After installing ver. 7.30.15.1114, try to install ver.7.30.16.1125 on top of it. Ver. 7.30.15.1114 will get uninstalled automatically and ver. 7.30.16.1125 will be installed. ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 11/14/2003 Version: 7.30.15.1114 ---------------------------------------------------------------------------------------------------------------------------------- Spyser Tracking #: DFCT 6216 Customer: HPQ Symptom: MegaMon Rebuilding messages contains corrupted strings. Fix: Compiled and build Spy code in Japanese version How to validate: Run Spy on Japanese OS, remove 1 drive from RAID1 and checck messages from MegaMon Tracking #: LSID100004906 Customer: HPQ Symptom: After installing Spy in Windows 2000, it creates a "LSI Logic Corporation" key under "HKEY_LOCAL_MACHINE\Software" in the registry. It has a "CERC IDE Utility" folder. Fix: Removed reference of "CERC IDE Utility" from the spyreg file. How to validate: Install Spy package, Look for "CERC IDE Utility" registry key, it should not be there. OEM Name: LSI Component: Windows Spy for MegaIDE ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 10/15/2003 Version: 7.30.14.1015 ---------------------------------------------------------------------------------------------------------------------------------- Windows Spy FEATURE ENHANCEMENT Enhancement # 1 Tracking #: TASK 5588 Customer: INTEL/ FSC Symptom: Model no. is not coming for SATA Controller in MCC Fix: Device ID for ICH5R and Hance Rapid is added in Spy How to validate: Run MCC on Intel ICH5R Controller (and also on Hance Rapid Controllers). Go to Controller properties and check for Model no. Bug Fixes Bug Fix # 1 Tracking #: DFCT 5585 Customer: INTEL Symptom: On drive Removal, RaidMon is showing message 2 times. Fix: For drive removal, Spy was sending message to Spy Event 2 times and hence RaidMon was showing message 2 time. One message is removed from Spy How to validate: Run Spy and RaidMon. Remove 1 drive from the system. Check for Messages that comes from RaidMon Bug Fix # 2 Tracking #: DFCT 5289 Customer: HPQ Symptom: String "Check Consistency completed with xx errors and yy mismatches on Logical Drive 0 " is not translated into Japanese Fix: In file EveMsg.mc above string is translated to Japanes How to validate: Run Spy on Japanese OS and check for message in NT Event Log Bug Fix # 3 Tracking #: DFCT 4235 Customer: INTEL Symptom: Drive removal message in NT Event viewer is not correct. It has 2 Colon marks. Message appears like this --> "Physical Drive :: Primary Master is removed". There should be just one colon mark. Fix: In resource file there were 2 colon marks. One colon mark is now removed How to validate: Run Spy and remove one drive. Check for message in NT Event Log Bug Fix # 4 Tracking #: DFCT 4906 Customer: INTEL Symptom: After installing Spy in Windows 2000, it creates a "LSI Logic Corporation" key under "HKEY_LOCAL_MACHINE\Software" in the registry. It has a "CERC IDE Utility" folder which is for Dell. Fix: Fixed in InstallShield How to validate: Try to duplicate it Bug Fix # 5 Tracking #: DFCT 5290 Customer: HPQ Symptom: In the Start-->Programs-->Raid Monitor-->Launch RaidMon. The word launch should be translated into Japanese, but displays in English. Fix: Fixed in InstallShield How to validate: Try to duplicate it OEM Name: LSI Component: Windows Spy for MegaIDE ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 10/15/2003 Version: 7.30.13.0915 ---------------------------------------------------------------------------------------------------------------------------------- Windows Spy Bug Fix #1 Tracking #: DFCT 4227 Customer: INTEL Symptom: On creating New Configuration, Junk characters appear in Spy.log file Fix: Spy was not converting message to unicode format for New configurations. How to validate: Run MegaManager and create "New Configuration". After creating configuration check for message in Spy.log file Bug Fix # 2 Tracking #: DFCT 4230 Customer: INTEL Symptom: RaidMon is showing messages too many times for Rebuilding Fix: Spy was sending message for Physical drive status change for each of the Logical Drive once. So there were repetitive messages. Now Spy checks for the no. of Logical Drives and is sending Physical Drive status change message only once How to validate: Create 2 or more Logical drives. Run Spy. Fail one drive and start rebuilding. You should see Physical drive status change message only once Bug Fix # 3 Tracking #: DFCT 4232 Customer: INTEL Symptom: In MegaManager, Physical Drive properties (IDE Standard) is coming as "Not Available" for SATA drives. It shopuld appear as SATA Fix: MegaManager gets IDE standard from call spy_get_model, and for SATA , model no. was no present. It is added now. How to validate: Run MegManager on SATA and check for Physical drive properties. Bug Fix # 4 Tracking #: DFCT 4234 Customer: INTEL Symptom: For SATA Controllers, Spy is showing drive names as Primary Master, Secondory Master etc. It should be PORT 0 , PORT 1 Fix: For SATA controllers drive names are changed from Primary Master to PORT # 0 , Secondory Master to PORT # 1 How to validate: Run Spy on SATA Controllers and check for messages in Spy.log , NT Event Log and messages from RaidMon Bug Fix # 4 RAID Monitor Tracking #: DFCT # 4236? Customer: INTEL Symptom: Drive insertion message from RaidMon shows "A new drive (0) has been inserted in Controller 0, channel 1" . For SATA Controller it should be Port instead of Channel Fix: Message in Resource string table is fixed. Instead of channel RaidMOn will now show Channel/Port . How to validate: Run RaidMon. Insert Drive and check for message that appear now. Enhancement # 1 Spyser Tracking #: DFCT 4228 Customer: INTEL Symptom: Model no. is not coming for SATA Controller in MCC Fix: Device ID for SATA controller is added in Spy How to validate: Run MCC on SATA Controller. Go to Controller properties and check for Model no. _________________________________________________________________________________________________ OEM Name: LSI Component: Windows Spy for MegaIDE ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 08/18/2003 Version: 7.30.12.0818 ---------------------------------------------------------------------------------------------------------------------------------- Windows Installer Bug Fix #1 Customer: HP Symptom: Two single executable were supplied to HP for English and Japanese, Now it will be only one single executable that will work on both English and Japanese. Fix: Now it will be only one single executable that will work on both English and Japanese. _________________________________________________________________________________________________ OEM Name: LSI Component: Windows Spy for MegaIDE ---------------------------------------------------------------------------------------------------------------------------------- Engineering Release Date: 08/15/2003 Version: 7.30.12.0815 ---------------------------------------------------------------------------------------------------------------------------------- Bug Fixes *LSID100003362 *Symptom: Spy 7.30.10/PSP 7.00 does not upgrade Spy. *Fix: When you have a previous version of the package installed and you try to install a new package, the old package will get uninstalled and new package will install.