This release note and the software that accompanies it are copyright (c) 2014, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using SAS software stack (RCS25ZB040, RCS25ZB040LX), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://support.intel.com. =================== Package Information =================== Flash package = v23.24.0-24 ========== Attention! ========== Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell command “ver" which will display the EFI version, to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: ir3_2208NMR_FWPKG-v23.24.0-24_readme.txt This file NMR17p.rom Firmware binary update.bat DOS firmware update batch file update.nsh UEFI firmware update batch file CmdTool2\DOS\* DOS update utility and support files CmdTool2\FreeBSD\* FreeBSD update utility and support files CmdTool2\Linux\* Linux update utility and support files CmdTool2\Solaris\* Solaris update utility and support files CmdTool2\UEFI\* UEFI update utility and support files CmdTool2\Windows\* Windows update utility and support files License_v2.pdf License Agreement COPYING.NEWLIB.txt License Agreement ========================== Installation instructions: ========================== UEFI (EFI 2.0) instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" or "efi\cmdtool2 -adpfwflash -f NMR17p.rom -noverchk -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. Windows and Linux instructions for updating RAID Firmware: ----------------- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2. In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f NMR17p.rom -aall". The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f NMR17p.rom -aall" DOS instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to DOS. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.bat" or "dos\cmdtool2 -adpfwflash -f NMR17p.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. You can also use RAID Web Console 2 to update the RAID firmware. For more detail, please refer to the Intel(R) RAID Software User's Guide. ============= Package Details/Fixes/Updates ============= 23.24.0-24 (NMR 1.7patch) Firmware v3.360.45-2817 SCGCQ00626600 - storcli is showing Read-Ahead Caching turned on by default on NytroCache VDs on new controllers and newly created NytroCache SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap SCGCQ00620276 - FW hangs when card is connected to certain bad SAS PDs SCGCQ00524966 - Metadata corrution issue noticed after replacing a failed card - Source VD gets blocked Cache Offload v3.200.15-0005 SCGCQ00554331 - Cache Offload firmware fails with device enquiry timeout with new NVDATA.rom SCGCQ00498721 - Using power analyzer, if the power in PCI slot is made back on within 150 ms after a power failure, COL failed to complete, as the chip is getting reset while COL in progress BIOS - v5.42.00 SCGCQ00408767 - OpROM not getting relocated to runtime segment if the segment address is 0xC0000 Hii - v03.61.02 SCGCQ00527665 - NMR1.7-UEFi HII shows evs volume as Virtual drive instead of (Nytro Virtual Drive ) UEFI_Driver - v0x06010300 FCODE - v4.14.05.00 SCGCQ00418701 - Not possible to probe a volume > 2Tb on Niwot raid card NVDATA - v2.1108.06-0010 SCGCQ00497877 - Disable, enable, silence Alarm option is shown in MSM for the galaxy controller SCGCQ00556525 - MonTask: line 280 in file ../../raid/1078int.c when set directpdmapping to ON WebBIOS - v6.5-64-e_64-Rel SCGCQ00574207 - WebBios displays option to locate onboard DFF PCLI - v05.07-00 SCGCQ00356037 SCGCQ00356190 - No controller properties for Online FW Update in MegaCLi Bootblock - v2.06.00.01-0000 Common Bootblock - v07.26.05.219 ROMENV - v1.08 23.13.0-0056 (NMR 1.5patch) Firmware v3.200.25-2490 - Reboot fails after upgrade of FW from older FW(2210) to newer FW(2477). 23.13.0-0046 (NMR 1.5) Firmware v3.200.25-2480 - After foreign config import VD properties are not reporting in the MSM - NMR1.5-Critical event OCR observed during OS bootup in OEM-specific server - CSA1.5 IntelZiaBeach: DFF moved to JBOD state after enabling JBOD from mfc settings of the controller - CSA1.5 IntelZiaBeach:2 out of 14 PD's are not configuring to JBOD state even though all PD's are in Unconfigured Good state - CSA 1.5: Source VD goes offline while copying large file from one VD to another VD (associated to Nytro Cache) - fixed in release order - MR_DCMD_CTRL_IO_METRICS_GET should return MFI_STAT_IO_METRICS_DISABLED if Io metrics collection is not enabled. Cache Offload v3.200.14-2073 - CSA1.5-Firmware crash observed after introducing lock out, pull the power cable BIOS - v5.35.00 Hii - v01.32.00 PCLI - v05.02-01 WebBIOS - v6.5-18-e_0-Rel - CSA1.5 :WEBBIOS hangs during source vd creation - CSA1.5 :WebBios Virtual Drive Erase option is not working for all the 3 variants of VD Erase! - CSA1.5 :WebBIOS 'Drive Erase' option for VD is not displaying the 'Delete VD option after Erase' checkbox option missing NVDATA - v2.1108.03-0090 Bootblock - v2.06.00.01-0000 Common Bootblock - v07.26.05.219 23.6.1-0004 (NMR 1.0) - Initial Release Firmware v3.200.15-2221 Cache Offload v3.200.14-1825 BIOS - v5.35.00 Hii - v01.32.00 PCLI - v05.02-01 WebBIOS - v6.5-8-e_0-Rel NVDATA - v2.1108.03-0088 Bootblock - v2.06.00.01-0000 Common Bootblock - v07.26.05.219 *Third-party trademarks are the property of their respective owners.