Personal Solution-Pac : General parameters file descritption ============================================================ Note : - Comments may be inserted in the parameter file by beginning the comment line with ; - Default installation file PSP_PAR.INI is saved in DEFAULT directory under PSP directory. General parameters [General] ============================ AutomaticStartup ---------------- 1 : automatic start of Personal Solution-Pac at system boot is enabled. 0 : automatic start is disabled. DelayAfterBoot (0 - 9999 seconds) --------------------------------- Delay between system initalization and effective start of PSP modules. PSP Monitoring Module parameters [Monitoring] ============================================= ShutdownDuration (0 - 9999 seconds) ----------------------------------- Duration of system shutdown. ShutdownTimer (0 - 9999 minutes) -------------------------------- Maximum time between power failure and system shutdown. LowBatteryTime (0 - 9999 seconds) --------------------------------- When UPS is on battery and battery remaining time goes under this minimum time, PSP start system shutdown (low battery condition). GracePeriod (0 - 9999 minutes) ------------------------------ Delay between utility failure and first utility failure notification to administrator and/or users. IntervalBetweenMessages (1 - 9999 minutes) ------------------------------------------ Delay between periodic messages sent to administrator and/or users after utility failure. DateTimeFormat -------------- Format string of date and time displayed in messages sent to administrator and/or users. The format string consists of one or more codes. The formatting codes are preceded by a percent sign (%). Characters that do not begin with % are displayed unchanged. Valid formatting codes are : %a Abbreviated weekday name %A Full weekday name %b Abbreviated month name %B Full month name %d Day of month as decimal number (01 - 31) %H Hour in 24-hour format (00 - 23) %I Hour in 12-hour format (01 - 12) %j Day of year as decimal number (001 - 366) %m Month as decimal number (01 - 12) %M Minute as decimal number (00 - 59) %S Second as decimal number (00 - 59) %U Week of year as decimal number, with Sunday as first day of week (00 - 51) %w Weekday as decimal number (0 - 6; Sunday is 0) %W Week of year as decimal number, with Monday as first day of week (00 - 51) %y Year without century, as decimal number (00 - 99) %Y Year with century, as decimal number %% Percent sign CommunicationDelay (60 - 9999 seconds) -------------------------------------- Maximum delay between Monitoring module start and communication is established with the UPS. TaskSchedulingRate (100 - 99999 milliseconds) --------------------------------------------- Internal delay between tasks. DownConfirmChar --------------- NetWare only : if specified, confirmation character pushed to system console to confirm system shutdown if files are left opened. PSP Communication Module parameters [Communication] =================================================== SerialPort ---------- Serial port used for communication with UPS. Windows 95 only : use "Auto" to enable automatic detection of serial port with a MGE UPS Systems "Plug and Play" UPS. BaudRate (2400 bauds) --------------------- Serial baud rate used for communication with UPS. UTalkTimeout (50 - 99999 milliseconds) -------------------------------------- Timeout for serial communication. MaxTimeoutError (1 - 9999) -------------------------- Maximum number of timeouts for serial communication with UPS. After this number of timeouts, serial communication is reinitialized. TaskSchedulingRate (100 - 99999 milliseconds) --------------------------------------------- Internal delay between tasks. PnPIdString ----------- Windows 95 only : Identification string for "Plug and Play" UPS detection. Inter-process communication parameters [Ipc] ============================================ ChannelWaitTimeout (1000 - 99999 milliseconds) ---------------------------------------------- Internal timeout delay for communication channels. CommandTimeout (500 - 99999 milliseconds) ----------------------------------------- Internal timeout for inter-process communication. TablePurgeDelay (1 - 9999 minutes) ---------------------------------- Purge delay of internal commands table buffer. Trace parameters [Trace] ======================== VerboseLevel (0-4) ------------------ Trace messages level. Windows NT : Using this parameter when modules are running as services will cause rapid growth of system application log. UPSTrace -------- 1 : serial communication is logged. 0 : serial communication is not logged. UPSTraceFile ------------ Serial communication log filename. UPSTraceFileSize (500 - 9999 lines) ----------------------------------- Serial communication log maximum size. File names and sizes [Files] ============================ LogScript --------- Script file that logs events. ShutdownScript -------------- Script file that starts system shutdown. BroadcastScript --------------- Script file that sends messages. ScheduleFile ------------ Customizable schedule filename. ActionFile ---------- Customizable actions filename. EventFile --------- Customizable events filename. LogFile ------- Event log filename. LogFileSize (500 - 9999 lines) ------------------------------ Event log maximum size. Commands activation flags ========================= The commands below are activated if the corresponding parameter is set to 1 and disabled if set to 0 Initialisation commands activation flags [InitCommands] ======================================================= Not applicable. Startup commands activation flags [StartupCommands] =================================================== If activated, this command is sent once after module starts. Bn? --- Command "Nominal Battery time" Monitoring commands activation flags [MonitoringCommands] ========================================================= If activated, these commands are sent periodically during the monitoring cycle. Bn -- Command "Battery time remaining" Us -- Command "Utility status" Ps -- Command "Bypass status" Ss -- Command "System status" Bs -- Command "Battery status" SStat ----- Pseudo-command "Serial status" Shutdown commands activation flags [ShutdownCommands] ===================================================== If activated, these commands are sent to turn UPS Off. SnX --- Command "Set remote shutdown delay" Sm0 --- Command "Set delay before Power On" Sx5 --- Command "Valid automatic restart" Sx0 --- Command "UPS OFF"